Générateurs pour les bâtiments


AGS-2/4 | With contact cooling

In terms of its design the AGS-2/4 resists vibration loads very well and therefore can be recommended for protection of means of transportation. It is also used in spaces with medium volume.

Protected volume : 21 m3 | Action period: 45 s | Weight: 4,6 kg
AGS-6/1 | With contact cooling

The AGS-6/1 is recommended for protecting electronic equipment, high voltage power units, various high frequency devices as well as for protecting means of transportation.

Protected volume : 3,2 m3 | Action period: 19 s | Weight: 1,0 kg | Old article: AGS-3
AGS-6/2 | With contact cooling

The AGS-6/2 can be recommended for fire-extinguishing systems inside medium volume spaces.

Protected volume : 52 m3 | Action period: 37 s | Weight: 12,5 kg | Old article: AGS-6
AGS-7/1 | With ejector cooling

The AGS-7/1 can be recommended for fire-extinguishing systems inside medium volume spaces.

Protected volume : 65 m3 | Action period: 86 s | Weight: 5,8 kg
AGS-7/2 | With ejector cooling

In terms of its design the AGS-7/2 resists vibration loads very well and therefore can be recommended for protection of means of transportation. It is also used in spaces with large volume.

Protected volume : 134 m3 | Action period: 165 s | Weight: 10,8 kg
AGS-8/1 | With labyrinth cooling

The AGS-8/1 can be recommended for fire-extinguishing systems inside medium volume spaces.

Protected volume : 60 m3 | Action period: 78 s | Weight: 10 kg
8-2.jpg
AGS-8/2 | With labyrinth cooling

The AGS-8/2 can be recommended for fire-extinguishing systems inside large volume spaces.

Protected volume : 124 m3 | Action period: 165 s | Weight: 18 kg
11-1.jpg
AGS-11/1 | Universal with air cooling

The AGS-11/1 is recommended for protecting electronic equipment, high voltage power units, various high frequency devices as well as for protecting means of transportation.

Protected volume: 2,2 m3 | Action period: 7 s | Weight: 0,6 kg
11-2.jpg
AGS-11/2| Universal with air cooling

The AGS-11/2 is recommended for protecting electronic equipment, high voltage power units, various high frequency devices as well as for protecting means of transportation.

Protected volume : 3,4 m3 | Action period: 11 s | Weight: 0,85 kg
11-3.jpg
AGS-11/3 | Universal with air cooling

The AGS-11/3is recommended for protecting electronic equipment, high voltage power units, various high frequency devices as well as for protecting means of transportation.

Protected volume : 6 m3 | Action period: 20 s | Weight: 1,2 kg
11-4.jpg
AGS-11/4 | Universal with air cooling

The AGS-11/4 is recommended for protecting electronic equipment, high voltage power units, various high frequency devices as well as for protecting means of transportation.

Protected volume : 18 m3 | Action period: 25 s | Weight: 2 kg
11-5.jpg
AGS-11/5 | Universal with air cooling

The AGS-11/5 is recommended for protecting electronic equipment, high voltage power units, various high frequency devices as well as for protecting means of transportation.

Protected volume : 28 m3 | Action period: 50 s | Weight: 4 kg
11-6.jpg
AGS-11/6 | Universal with air cooling

The AGS-11/6 is recommended for protecting electronic equipment, high voltage power units, various high frequency devices as well as for protecting means of transportation.

Protected volume : 48 m3 | Action period: 40 s | Weight: 4,8 kg

Générateurs d'aérosol extincteur sont conçu pour éteindre les incendies par aérosol. L'élément principal d'un tel dispositif est une charge spéciale pyrotechnique dans la combustion duquel se forme un aérosol.

Les générateurs d'aérosol extincteur présentés dans cette section de notre catalogue seulement sont utilisés à l'intérieur. L'utilisation de ces dispositifs dans les espaces ouverts est impraticable: l'aérosol se dissipe rapidement, ce qui réduit considérablement l'efficacité du énérateurs.

Les générateurs d'aérosol extincteur, lequel on peut acheter dans notre société, présente les avantages suivants:
  • Haute performance: les énérateurs peut être utilisé pour éteindre les incendies les plus difficiles dans les espaces d'un grand volume;
  • Respect de l'environnement: énérateurs n'émettent pas dans l'atmosphère des composés qui ont un impact négatif sur l'environnement;
  • La sécurité des biens et des équipements: cet avantage est dû aux propriétés de l'aérosol généré lors de lutte contre l'incendie;
  • La facilité d'installation et la maintenance ultérieure;
  • Abordabilité.