Generators for buildings


AGS-2/4 | With contact cooling

In terms of its design the AGS-2/4 resists vibration loads very well and therefore can be recommended for protection of means of transportation. It is also used in spaces with medium volume.

Protected volume : 21 m3 | Action period: 45 s | Weight: 4,6 kg
AGS-6/1 | With contact cooling

The AGS-6/1 is recommended for protecting electronic equipment, high voltage power units, various high frequency devices as well as for protecting means of transportation.

Protected volume : 3,2 m3 | Action period: 19 s | Weight: 1,0 kg | Old article: AGS-3
AGS-6/2 | With contact cooling

The AGS-6/2 can be recommended for fire-extinguishing systems inside medium volume spaces.

Protected volume : 52 m3 | Action period: 37 s | Weight: 12,5 kg | Old article: AGS-6
AGS-7/1 | With ejector cooling

The AGS-7/1 can be recommended for fire-extinguishing systems inside medium volume spaces.

Protected volume : 65 m3 | Action period: 86 s | Weight: 5,8 kg
AGS-7/2 | With ejector cooling

In terms of its design the AGS-7/2 resists vibration loads very well and therefore can be recommended for protection of means of transportation. It is also used in spaces with large volume.

Protected volume : 134 m3 | Action period: 165 s | Weight: 10,8 kg
AGS-8/1 | With labyrinth cooling

The AGS-8/1 can be recommended for fire-extinguishing systems inside medium volume spaces.

Protected volume : 60 m3 | Action period: 78 s | Weight: 10 kg
8-2.jpg
AGS-8/2 | With labyrinth cooling

The AGS-8/2 can be recommended for fire-extinguishing systems inside large volume spaces.

Protected volume : 124 m3 | Action period: 165 s | Weight: 18 kg
11-1.jpg
AGS-11/1 | Universal with air cooling

The AGS-11/1 is recommended for protecting electronic equipment, high voltage power units, various high frequency devices as well as for protecting means of transportation.

Protected volume: 2,2 m3 | Action period: 7 s | Weight: 0,6 kg
11-2.jpg
AGS-11/2| Universal with air cooling

The AGS-11/2 is recommended for protecting electronic equipment, high voltage power units, various high frequency devices as well as for protecting means of transportation.

Protected volume : 3,4 m3 | Action period: 11 s | Weight: 0,85 kg
11-3.jpg
AGS-11/3 | Universal with air cooling

The AGS-11/3is recommended for protecting electronic equipment, high voltage power units, various high frequency devices as well as for protecting means of transportation.

Protected volume : 6 m3 | Action period: 20 s | Weight: 1,2 kg
11-4.jpg
AGS-11/4 | Universal with air cooling

The AGS-11/4 is recommended for protecting electronic equipment, high voltage power units, various high frequency devices as well as for protecting means of transportation.

Protected volume : 18 m3 | Action period: 25 s | Weight: 2 kg
11-5.jpg
AGS-11/5 | Universal with air cooling

The AGS-11/5 is recommended for protecting electronic equipment, high voltage power units, various high frequency devices as well as for protecting means of transportation.

Protected volume : 28 m3 | Action period: 50 s | Weight: 4 kg
11-6.jpg
AGS-11/6 | Universal with air cooling

The AGS-11/6 is recommended for protecting electronic equipment, high voltage power units, various high frequency devices as well as for protecting means of transportation.

Protected volume : 48 m3 | Action period: 40 s | Weight: 4,8 kg

Aerosol fire-extinguishing generators are intended for extinction of deflagrations with aerosol. The main component of these devices is a special pyrotechnic charge whose combustion leads to formation of aerosol.

Fire-extinguishing aerosol generators described in this section of our catalogue are only used in closed spaces. Using these devices in open spaces is unreasonable due to fast aerosol dispersal which greatly reduces the efficiency of fire-extinguishing aerosol generators.

The fire-extinguishing aerosol generators which can be purchased from our company have the following advantages:
  • high efficiency: fire-extinguishing aerosol generators can be used for extinguishing most difficult deflagrations in spaces of large volume;
  • environmental friendliness: fire-extinguishing aerosol generators inject into the atmosphere no compounds which may impair the environment;
  • safety for property and equipment due to the properties of the aerosol generated during the fire-fighting process;
  • easy installation and further maintenance;
  • accessible prices.